Skip to main content
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI) Paul Scherrer Institut (PSI)
Suche
Paul Scherrer Institut (PSI) Paul Scherrer Institut (PSI)

Hauptnavigation

  • Labs & User ServicesOpen mainmenu item
    • Overview
    • Research at PSI
    • Research Divisions and Labs
    • Facilities and Instruments
    • Research Initiatives
    • PSI User Labs
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • Useroffice
  • VisitorsOpen mainmenu item
    • Overview
    • Contact
    • How to find us
    • Public Events
    • Visitor Centre psi forum
    • Schülerlabor iLab
    • Center for Proton Therapy
  • IndustryOpen mainmenu item
    • Overview
    • Technology Transfer
    • Spin-off Companies
    • PARK innovAARE
  • Our ResearchOpen mainmenu item
    • Current topics from our research
    • Matter and Material
    • Human Health
    • Energy and Environment
    • Large Research Facilities
    • Brochures
    • Films
    • Media Corner
  • Career & Further EducationOpen mainmenu item
    • Job Opportunities
    • Personnel Policy
    • Working at PSI
    • Equal Opportunities, Diversity & Inclusion
    • Training and Further Education
    • Vocational Training
    • PSI Education Centre
    • Support Program "PSI Career Return Program"
    • PSI-FELLOW/COFUND
  • About PSIOpen mainmenu item
    • PSI in brief
    • Strategy
    • Guiding principles
    • Facts and figures
    • Organisational structure
    • Suppliers and customers
    • Customers E-Billing
    • IT and Computing
    • Safety at PSI (in German)

You are here:

  1. PSI Home
  2. Labs & User Services
  3. PSD
  4. SLS
  5. TOMCAT
  6. Beamline Information
  7. Beamline Optics

Secondary navigation

TOMCAT

  • Beamline Information Expanded submenu item
    • Source
    • Beamline Optics
    • Endstations
    • Detectors
  • User Information
    • Safety
    • Technique Principles
    • Operation Schedule
    • Submitting Proposals
    • Prepare for beamtime
    • During beamtime
    • After a beamtime
    • Computing Infrastructure
  • People
  • Research
  • Industrial Services
  • Download
  • Publications
  • Scientific Highlights
  • News Archive
  • Contacts

Beamline Optics

Rationale: Real space, full-field imaging, and in particular tomography, needs a homogeneous and stable beam profile, in order to perform optimal background corrections. Because of the high coherence of the radiation produced by third-generation synchrotron radiation facilities like the SLS, all the optical components (windows, mirrors and monochromator) must be designed with particular care in order to avoid deterioration of the beam profile. The design criteria for the optics of the TOMCAT beamline have been:
  • Simplify the optics (i.e., minimize the number of optical elements)
  • Optimize optics for bandwidth rather than for energy resolution
  • Make monochromatic beam and white beam available
  • Energy range: 8-45 keV
Window: The machine UHV-sector (10-10 mbar) is separated from the beamline HV (10-7 mbar) by a Chemical Vapour Deposited (CVD) diamond window, (see below). Because of the better surface-roughness, CVD diamond windows are preferred to standard Be-windows. The thickness of the window is 100μm, its surface-roughness is 2.5 nm RMS. The coherence degradation due to the window has been measured with shearing interferometry and is negligible.


CVD diamond window support, with cooling pipes
CVD diamond window support, with cooling pipes
Roughness measurement of the diamond thin film
Roughness measurement of the diamond thin film



Optics The main optical component of the TOMCAT beamline is a fixed-exit double crystal multilayer monochromator (DCMM) which covers an energy range from 8 to 45 keV. Design and manufacturing have been done by CINEL Strumenti Scientifici from Italy. The DCMM is located in the front-end, at approximately 7 m from the source: this allows it to accept a large angular divergence while keeping the optical elements very compact. [Ru/C]100 and a [W/Si]100 multilayer stripes have been coated 8 mm apart from each other on a Si111 substrate (active area of 150x50 mm2). As a result, the energy bandwidth of the DCMM is a few percent when multilayer are used or 10-4 when the silicon is used. The slope errors in the direction along and across the optic are better than 0.5 μrad RMS and 5 μrad RMS respectively. Surface roughness is less than 0.3 nm RMS. When operating with multilayers the Bragg angle varies between θ = 1.82° and θ = 0.265° for energies ranging from 5 keV up to 45 keV. For the low-energy settings, the power density is 80 mW/mm2 and is dissipated via water cooling. The crystal optics are mounted on two independent high-precision goniometers. The first crystal has motorized pitch, roll, and horizontal translation (for stripes selection); the second crystal has the same degrees of freedom and, in addition, yaw and vertical translation. The whole system is positioned on a base plate that can be vertically adjusted. The distance between both crystals can be increased up to 850 mm. Instead of using a collimating mirror, the vertical size of the beam is controlled by moving the endstation along the beam path (up to 15 m travel range).


Left: View of the sector 2 of the SLS tunnel: visible are the magnets of the storage ring (in the foreground) as well as the TOMCAT front end (background). The monochromator vacuum chamber is clearly visible on the right side. Right: View of the mechanics of the mono: the multilayer crystals are mounted on two separate goniometer towers. The first crystal can be adjusted in transverse direction as well as in pitch and roll. The second crystal has transverse, longitudinal (up to 850 mm range), vertical as w…
Left: View of the sector 2 of the SLS tunnel: visible are the magnets of the storage ring (in the foreground) as well as the TOMCAT front end (background). The monochromator vacuum chamber is clearly visible on the right side.
Right: View of the mechanics of the mono: the multilayer crystals are mounted on two separate goniometer towers. The first crystal can be adjusted in transverse direction as well as in pitch and roll. The second crystal has transverse, longitudinal (up to 850 mm range), vertical as well as pitch, roll and yaw adjustments. Both crystals are supported by a bank which is vertically translated and tilted by three jacks.



Monochromatic Operation: The expected multilayer/crystal translations are shown below. The beam offset will be between 7 and 10 mm for multilayers and 25 mm for the Si111.
Energy Range 8-45 keV
Energy bandwidth 2-3 % with multilayers
0.018% with Si111
Photon Flux (ph/s) with multilayers > 5e14 @ 10 keV
> 3e14 @ 20 keV
> 1e14 @ 40 keV
Beam Size @ 20 m from source 40 mm (H) x 4-7 mm (V) for energies between 10-30 keV

Expected translation of the second crystal along the beam path when multilayers are used. (Click to enlarge)
Expected translation of the second crystal along the beam path when multilayers are used. (Click to enlarge)
Expected translation of the second crystal along the beam path when Si111 crystal is used. (Click to enlarge)
Expected translation of the second crystal along the beam path when Si111 crystal is used. (Click to enlarge)



White beam operation: The DCMM can be easily removed from the beam path and white beam radiation can be provided at the endstation. Filter batteries (Four quadruple and one triple) are available to pre-condition the radiation.
Beam Size @ 20 m from source 40 mm (H) x 9 mm (V)
Filter Battery 0 5 mm pyrolitic graphite, 20 mm pyrolitic graphite, 20 mm pyrolitic graphite + 75 μm Pd
Filter Battery 1 100 μm, 200 μm, 400 μm Al, 20 μm Cu
Filter Battery 2 50 μm Al, 10 μm, 40 μm, 50 μm Al
Filter Battery 3 10 μm , 50 μm Fe, 10 μm Cu, 100 μm Al
Filter Battery 4 10 μm Cu, 100 μm Al, 200 μm Al
The expected performance of the multilayer monochromator (bandwidth between 2-3 %) is depicted in the graph below.





Sidebar

Beamlines at SLS

Get an overview of beamlines at the SLS
top

Footer

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Switzerland
How to find us

Imprint
Terms and Conditions

Login

Telephone: +41 56 310 21 11
Telefax: +41 56 310 21 99
Contact form

Visitor Centre psi forum
School Lab iLab (in German)
Center for Proton Therapy

Follow us: Twitter (in English) LinkedIn Youtube Issuu RSS

Quicklinks

  • Phone Book/People Search
  • Digital User Office
  • Technology transfer
  • PSI Publications
  • Computing
  • Safety (in German)
  • Job Opportunities
  • Vocational Training (in German)
  • Suppliers
  • Customers E-Billing
  • PSI Guest House
  • PSI Gastronomie (in German)

For the media

  • PSI in brief
  • Facts and Figures
  • Media Contact
  • Media Releases
  • Social Media Newsroom
  • DE
  • EN
  • FR