Skip to main content
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI) Paul Scherrer Institut (PSI)
Suche
Paul Scherrer Institut (PSI) Paul Scherrer Institut (PSI)

Hauptnavigation

  • Labs & User ServicesOpen mainmenu item
    • Overview
    • Research at PSI
    • Research Divisions and Labs
    • Facilities and Instruments
    • Research Initiatives
    • PSI User Labs
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • Useroffice
  • VisitorsOpen mainmenu item
    • Overview
    • Contact
    • How to find us
    • Public Events
    • Visitor Centre psi forum
    • Schülerlabor iLab
    • Center for Proton Therapy
  • IndustryOpen mainmenu item
    • Overview
    • Technology Transfer
    • Spin-off Companies
    • PARK innovAARE
  • Our ResearchOpen mainmenu item
    • Current topics from our research
    • Matter and Material
    • Human Health
    • Energy and Environment
    • Large Research Facilities
    • Brochures
    • Films
    • Media Corner
  • Career & Further EducationOpen mainmenu item
    • Job Opportunities
    • Personnel Policy
    • Working at PSI
    • Equal Opportunities, Diversity & Inclusion
    • Training and Further Education
    • Vocational Training
    • PSI Education Centre
    • Support Program "PSI Career Return Program"
    • PSI-FELLOW/COFUND
  • About PSIOpen mainmenu item
    • PSI in brief
    • Strategy
    • Guiding principles
    • Facts and figures
    • Organisational structure
    • Suppliers and customers
    • Customers E-Billing
    • IT and Computing
    • Safety at PSI (in German)

You are here:

  1. PSI Home
  2. Labs & User Services
  3. NES
  4. LRT
  5. Sacre
  6. Projects
  7. FCVS

Secondary navigation

Severe Accident Research Group

  • Team
  • Facilities
  • Projects
  • Scientific Highlight
  • Tools
  • Teaching and Education
    • PhD Theses
  • Journal Publications
    • Journal 2020
    • Journal 2019
  • Conference Articles
  • International Reports
  • Public News

Filtered Containment Venting Systems (FCVS)

The filtered containment venting system is recognized to be an efficient measure to reduce release of radioactivity to the environment in the accident sequences when the containment pressure needs to be reduced to avoid failure of the containment. Many reactors worldwide, and all the Swiss nuclear power plants (NPP) have installed FCVS. After the Fukushima accidents many additional countries have required FCVSs to be installed in their reactors. This project is an experimental investigation of the source term mitigation using FCVS with a focus on wet scrubbers. The wet scrubber systems are generally accepted as having a very high collection efficiency for aerosols under their optimum operation conditions, even though they have a minimum collection efficiency in the particle size range 0.2-0.3 µm (aerodynamic diameter). However, when the conditions are not in the optimal range due to, e.g., decreased water inventory, or the flow rate is outside of the design range, the collection efficiency of the scrubbers decreases. In addition, radioactivity may escape from the scrubbers if droplets are entrained from the pool surface carrying soluble compounds with them, e.g., Cs, and I. Droplet formation may be expected under very high flow rates in the scrubbers, or under boiling conditions due to long-term containment depressurization through the FCVS. Iodine retention for both molecular iodine and organic iodide species in the pools during several venting cycles as well as under varying conditions in the pool, e.g., hot pool, low pH, are further open issues. This project focuses on some of the topics which have not been thoroughly addressed in earlier work:
  • Aerosol retention in the FCVS when the flow rate through the FCVS is very low and the inertial forces acting on the particles close to the injection point are relatively small
  • Aerosol retention in the FCVS when the flow rate through the FCVS is very high and droplet formation on the pool surface may occur
  • Aerosol retention when the water in the FCVS is boiling, and increased release of fission products may occur due to carry-over of soluble material in the droplets and steam
  • Iodine retention during multiple venting cycles
  • Long-term behavior of iodine in the scrubber solution
  • Test of additives in the water to retain organic iodine

Sidebar

Contact

Research Division
Nuclear Energy and Safety (NES)
Laboratory for Reactor-Physics and Thermal-Hydraulics (LRT)
Paul Scherrer Institute
5232 Villigen PSI
Switzerland

Group Leader a.i.
Dr. Detlef Suckow

Office: OHSA/C04
+41 56 310 4145
detlef.suckow@psi.ch

Members Area

top

Footer

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Switzerland
How to find us

Imprint
Terms and Conditions

Login

Telephone: +41 56 310 21 11
Telefax: +41 56 310 21 99
Contact form

Visitor Centre psi forum
School Lab iLab (in German)
Center for Proton Therapy

Follow us: Twitter (in English) LinkedIn Youtube Issuu RSS

Quicklinks

  • Phone Book/People Search
  • Digital User Office
  • Technology transfer
  • PSI Publications
  • Computing
  • Safety (in German)
  • Job Opportunities
  • Vocational Training (in German)
  • Suppliers
  • Customers E-Billing
  • PSI Guest House
  • PSI Gastronomie (in German)

For the media

  • Media Contact
  • Media Releases
  • Social Media Newsroom
  • Facts and Figures
  • PSI in brief
  • Films
  • DE
  • EN
  • FR