Direkt zum Inhalt
  • Paul Scherrer Institut PSI
  • PSI Research, Labs & User Services

Digital User Office

  • Digital User Office
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI)
Suche
Paul Scherrer Institut (PSI)

Hauptnavigation

  • Research at PSIÖffnen dieses Hauptmenu Punktes
    • Research Initiatives
    • Ethics and Research integrity
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • PSI-FELLOW
    • PSI Data Policy
  • Research Divisions and LabsÖffnen dieses Hauptmenu Punktes
    • Overview
    • Research with Neutrons and Muons
    • Photon Science
    • Energy and Environment
    • Nuclear Energy and Safety
    • Biology and Chemistry
    • Scientific Computing, Theory and Data
    • Large Research Facilities
  • Facilities and InstrumentsÖffnen dieses Hauptmenu Punktes
    • Overview
    • Large Research Facilities
    • Facilities
    • PSI Facility Newsletter
  • PSI User ServicesÖffnen dieses Hauptmenu Punktes
    • User Office
    • Methods at the PSI User Facilities
    • Proposals for beam time
    • Proposal Deadlines
    • Data Analysis Service (PSD)
    • EU support programmes
  • New ProjectsÖffnen dieses Hauptmenu Punktes
    • SLS 2.0
    • IMPACT
  • DE
  • EN
  • FR

Digital User Office (mobile)

  • Digital User Office

Sie befinden sich hier:

  1. PSI Home
  2. Labs & User Services
  3. PSD
  4. LXN
  5. Research Groups
  6. X-ray Nano-Optics
  7. X-ray Optics for XFELs
  8. A Delay Line for Ultrafast Pump-Probe Experiments

Sekundäre Navigation

Laboratory for X-ray Nanoscience and Technologies (LXN)

  • About LXN
    • Organisational Structure
  • Open Positions
  • People
  • Research Groups Ausgeklappter Submenü Punkt
    • X-ray Nano-Optics Ausgeklappter Submenü Punkt
      • X-ray Optics for Imaging and Spectroscopy
        • Fresnel Zone Plate for X-ray Microscopy
        • Blazed X-ray Optics
        • Zernike X-ray Phase Contrast Microscopy
        • Fresnel Zone Plates for RIXS
        • Refractive Lenses by 2 Photon 3D Lithography
      • Wavefront Metrology and Manipulation
        • Vortex Fresnel Zone Plates
        • Grating-based Wavefront Metrology
      • X-ray Optics for XFELs Ausgeklappter Submenü Punkt
        • Diamond Fresnel Zone Plates
        • Beam Splitter Gratings for Spectral Monitoring
        • A Delay Line for Ultrafast Pump-Probe Experiments
        • X-ray Streaking for Ultrafast Processes
    • Molecular Nanoscience
      • On-surface Chemistry
      • Spins in Molecular Monolayers
      • SiC: Surfaces and Interfaces
      • Our Research Team
    • Advanced Lithography and Metrology
      • EUV Interference Lithography
      • EUV Lensless Imaging
      • ALM Nanoscience
    • Quantum Photon Science
      • News and highlights
      • People
      • Open positions
      • Current projects
        • Imaging quantum many-body states
        • Nonlinear magnonics
        • Optical devices & methods
        • Rare-earth quantum magnets
        • Rydberg states in Si ∂-layers
        • Strained Ge laser (former research activity of H. Sigg & collaborators)
        • Van der Waals materials & devices
      • Infrastructure
        • Cristallina-Q
        • IR beamline
        • Nano-fabrication
      • Publications
      • QTC@PSI
    • Detectors
      • Projects
        • MYTHEN
        • GOTTHARD
        • EIGER
        • JUNGFRAU
        • MOENCH
        • AGIPD
        • Documentation
        • Software Releases
      • Research
      • Detectors Scientific Highlights
      • Publications
      • Team
  • Facilities and Equipment
    • Surface Science Lab
    • Scanning Electron Microscopy
    • Scanning Probe Microscopy
    • PEARL Beamline
    • XIL Facility at the SLS
    • Cleanroom Labs
  • Scientific Highlights and News
    • Archive
  • Publications
    • Archive

Info message

Dieser Inhalt ist nicht auf Deutsch verfügbar.

A Delay Line for Ultrafast Pump-Probe Experiments

Figure 1: Diffraction gratings are used to create a multiple split-and-delay line. The undiffracted (direct) beam serves as a pump, and can be attenuated and focused independently by X-ray lens 2. The beams diffracted upwards by the splitter gratings Sn are redirected towards the sample by the recombiner gratings Rn, and probe the pumped sample region with defined delays. The beams diffracted downwards by Sn are steered to a region of the sample that is slightly below the pump beam (see inset) to provide r…
Figure 1: Diffraction gratings are used to create a multiple split-and-delay line. The undiffracted (direct) beam serves as a pump, and can be attenuated and focused independently by X-ray lens 2. The beams diffracted upwards by the splitter gratings Sn are redirected towards the sample by the recombiner gratings Rn, and probe the pumped sample region with defined delays. The beams diffracted downwards by Sn are steered to a region of the sample that is slightly below the pump beam (see inset) to provide reference signals of the unpumped response on the very same shot. All beams are recorded separately on a detector array. Only three delayed beam pairs are shown for simplicity.
Due to their femtosecond time structure, XFELs are successfully used for the investigation of ultrafast phenomena. In such pump-probe measurements, the sample is excited by a a short „pump“ pulse and then probed by a second „probe“ pulse after a certain delay time. Therefore, the sample's full dynamics must be obtained by repeating multiple measurements at different delay times. We (X-Ray Optics Group @ LMN, with support of cSAXS Beam line & Detector Group @ SLS and SwissFEL) developed a novel delay line based on diffraction gratings. It splits several beams from an XFEL pulse and recombines them at the sample. Each undiffracted (pump) pulse is therfore followed by a sequence of diffracted beams with precisely defined delays. Downstream of the sample, the beams separate again and can be recorded on an x-ray detector array. In addition to the probe beams, we also create a series of reference beams with the same delays, that hit the sample in an unpumped region. The schematic figure shows only 3 diffracted beam pairs for simplicity – corresponding to three different delay times. In our LCLS experiment, we created up to 15 probe and reference beam pairs (Figure 1).


Figure 2: Single-shot time resolved X-ray diffraction measurements. The experimental geometry is the one depicted in Fig. 1, however using a 2-dimensional pixel detector. Panels a) - d) show the signal of the probe and reference beams on a logarithmic scale (log10). Panel a) was recorded with the pump beam blocked upstream of the sample, panels b) – d) display three single shot measurements at the full pump power density of 3×1014 W/cm2, meaning that no attenuators were used in the pump beam. Panel e) show…
Figure 2: Single-shot time resolved X-ray diffraction measurements. The experimental geometry is the one depicted in Fig. 1, however using a 2-dimensional pixel detector. Panels a) - d) show the signal of the probe and reference beams on a logarithmic scale (log10). Panel a) was recorded with the pump beam blocked upstream of the sample, panels b) – d) display three single shot measurements at the full pump power density of 3×1014 W/cm2, meaning that no attenuators were used in the pump beam. Panel e) shows the in-tensities integrated over the spots of b) – d), normalized with the corresponding intensities of a), versus delay time. The probe pulses decay due to the destruction of the Bi crystal lattice, whereas the reference signals remain constant.
Technically, the main challenge lies in the grating fabrication. The beam splitter gratings must be made from diamond in order not to be destroyed by the beam. The grating lines must be extremely fine to get delay times up to 1 ps, this required gratings with periods down to 17 nm. In addition, the setup must be fairly Long. We used a distance of 12.2 m between the first grating and the sample. In an experiment at LCLS, we observed how the Bragg reflectivity of a crystal changes after being pumped by the undiffracted XFEL pulse. Each data point in the plot represents a beam diffracted by the gratings. While the signal from the reference beams reflected from an unpumped region on the sample stays essentially constant, the probe signals from the pumped region drops with a half-time of about 50 fs, as the crystal structure is destroyed by the pump pulse. This represents the very first „single pump – multiple probe“ experiment, showing that the time trace of irreversible, destructive processes can be observed [1,2].

Similar experiments on the de-magnetization dynamics of ferromagnets [3] and on the damage processes on protein crystals [4] have been performed.


Publications

  1. C. David, P. Karvinen, M. Sikorski, I. Vartiainen, S. Song, C.J. Milne, A. Mozzanica, Y. Kayser, A. Diaz, I. Mohacsi, G. Carini, S. Herrmann, E. Färm, M. Ritala, D.M. Fritz, and A. Robert, Following the dynamics of matter with femtosecond precision using the X-ray streaking method, Scientific Reports 5 (2014) p. 7644
  2. M. Makita, I. Vartiainen, I. Mohacsi, C. Caleman, A. Diaz, O. Jonsson, P. Juranic, N. Medvedev, A. Meents, A. Mozzanica, N. Opara, C. Padeste, V. Panneels, V. Saxena, M. Sikorski, S. Song, L. Vera, P. Willmott, P. Beaud, C. Milne, B. Ziaja-Motyka, and C. David, X-ray induced non-thermal melting of Bismuth at femto-second time scales,Scientific Reports 9 (2018) p. 602, DOI:10.1038/s41598-018-36216-3
  3. M. Buzzi, M. Makita, L. Howald, A. Kleibert, B. Vodungbo, P. Maldonado, J. Raabe, N. Jaouen, H. Redlin, K. Tiedtke, P.M. Oppeneer, C. David, F. Nolting, J. Lüning, Single-shot Monitoring of Ultrafast Processes via X-ray Streaking at a Free Electron Laser, Scientific Reports 7 (2017) p. 7253, DOI: 10.1038/s41598-017-07069-z
  4. N. Opara, I. Mohacsi, M. Makita, D. Castano-Diez, A. Diaz, P. Juranic, M. Marsh, A. Meents, C. Milne, C. Padeste, V. Panneels, M. Sikorski, S. Song, H. Stahlberg, I. Vartiainen, L. Vera, M. Wang, P. Willmott, C. David, Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals, Structural Dynamics 5 (2018) p. 054303-9, DOI: 10.1063/1.5050618

Mit Sidebar

Contact

Dr. Christian David

Laboratory for X-ray Nano-Optics
Paul Scherrer Institut
5232 Villigen PSI
Switzerland

Telephone: +41 56 310 37 53
E-mail: christian.david@psi.ch

top

Fussbereich

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Schweiz

Telefon: +41 56 310 21 11
Telefax: +41 56 310 21 99

Der Weg zu uns
Kontakt

Besucherzentrum psi forum
Schülerlabor iLab
Zentrum für Protonentherapie
PSI Bildungszentrum
PSI Guest House (in english)
PSI Gastronomie
psi forum-Shop

 

Service & Support

  • Telefonbuch
  • User Office
  • Accelerator Status
  • Publikationen des PSI
  • Lieferanten
  • E-Rechnung
  • Computing
  • Sicherheit

Karriere

  • Arbeiten am PSI
  • Stellenangebote
  • Aus- und Weiterbildung
  • Career Center
  • Berufsbildung
  • PSI Bildungszentrum

Für die Medien

  • Das PSI in Kürze
  • Zahlen und Fakten
  • Mediacorner
  • Medienmitteilungen
  • Social Media

Folgen Sie uns: Twitter (deutsch) LinkedIn Youtube Facebook Instagram Issuu RSS

Footer legal

  • Impressum
  • Nutzungsbedingungen
  • Editoren-Login