Direkt zum Inhalt
  • Paul Scherrer Institut PSI
  • PSI Research, Labs & User Services

Digital User Office

  • Digital User Office
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI)
Suche
Paul Scherrer Institut (PSI)

Hauptnavigation

  • Research at PSIÖffnen dieses Hauptmenu Punktes
    • Research Initiatives
    • Research Integrity
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • PSI-FELLOW
    • PSI Data Policy
  • Research Divisions and LabsÖffnen dieses Hauptmenu Punktes
    • Overview
    • Research with Neutrons and Muons
    • Photon Science
    • Energy and Environment
    • Nuclear Energy and Safety
    • Biology and Chemistry
    • Large Research Facilities
  • Facilities and InstrumentsÖffnen dieses Hauptmenu Punktes
    • Overview
    • Large Research Facilities
    • Facilities
    • PSI Facility Newsletter
  • PSI User ServicesÖffnen dieses Hauptmenu Punktes
    • User Office
    • Methods at the PSI User Facilities
    • Proposals for beam time
    • Proposal Deadlines
    • Data Analysis Service (PSD)
    • EU support programmes
  • DE
  • EN
  • FR

Digital User Office (mobile)

  • Digital User Office

Sie befinden sich hier:

  1. PSI Home
  2. Labs & User Services
  3. PSD
  4. SLS
  5. ADRESS
  6. Beamline Layout
  7. Optics

Sekundäre Navigation

ADRESS

  • Status
  • User Information
    • Operation Schedule
    • Manuals
  • People
  • Beamline Layout Ausgeklappter Submenü Punkt
    • Source
    • Optics
  • Endstations
  • Scientific Highlights and News
  • Publications
  • Contacts

Info message

Dieser Inhalt ist nicht auf Deutsch verfügbar.

Beamline Optics

The optical scheme of the beamline adopts the concept of the Plane Grating Monochromator (PGM) operated in collimated light (Figure 1). This optical scheme benefits from high resolution, high flux, wide energy range and operation at variable Cff parameters allowing resolution and flux optimization. The collimating mirror (CM) is a toroid which converts the divergent beam from the source into the beam collimated in the vertical (dispersive) plane. The monochromator situated downstream consists of a plane pre-mirror (PM) and selectable gratings, dispersing the beam in photon energies. Three exchangeable gratings are used to provide optimal coverage of the flux and resolution: a blazed 800 l/mm one for maximal flux, lamellar 2000, and 4200 l/mm for maximal resolution. Downstream the monochromator is the focussing mirror (FM) which is a cylinder to focus the dispersed collimated beam on the exit slit, producing monochromatic light. In the horizontal (non-dispersive) plane, the FM has no focusing properties, and the beam from the undulator is directly focused by the CM on the exit slit, producing here a stigmatic focus. The first refocusing mirror (RM1) is a toroid which refocuses the beam on the sample in the first SX-ARPES endstation. When the RM1 is shifted away from the beam path, the second refocusing mirror (RM2) having an ellipsoidal shape refocuses the beam to the second RIXS endstation to bring the vertical spot size down to 4 µm as required for slitless operation of the RIXS spectrometer. The refocusing mirrors are mounted at high-precision hexapod mechanics.

The experimentally confirmed resolution and flux parameters of the beamline are presented in Figure 2. With soft-X-ray RIXS and ARPES, two photon-hungry experimental techniques, the key performance element is the high flux, which has resulted from the SLS storage ring energy of 2.4 GeV exactly matching the soft-X-ray region, and optimized optical scheme with glancing incidence on the mirrors, optimized grating profiles and operation at flux-optimal Cff values. The performance level of ADRESS makes it presently the forefront soft-X-ray beamline. Its extremely reliable operation can be characterized by basically zero downtime during the last few years.


Figure 1: Optical scheme
Figure 1: Optical scheme
Figure 2: Resolving power and flux parameters. The lines corresponds to different Cff.
Figure 2: Resolving power and flux parameters. The lines corresponds to different Cff.

Mit Sidebar

Beamlines at SLS

Get an overview of beamlines at the SLS
top

Fussbereich

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Schweiz

Telefon: +41 56 310 21 11
Telefax: +41 56 310 21 99

Der Weg zu uns
Kontaktformular

Besucherzentrum psi forum
Schülerlabor iLab
Zentrum für Protonentherapie
PSI Bildungszentrum
PSI Guest House (in english)
PSI Gastronomie

Service & Support

  • Telefonbuch/​Personensuche
  • User Office
  • Accelerator Status
  • Publikationen des PSI
  • Lieferanten
  • E-Rechnung
  • Computing
  • Sicherheit

Karriere

  • Arbeiten am PSI
  • Stellenangebote