Aller au contenu principal
  • Paul Scherrer Institut PSI
  • PSI Research, Labs & User Services

Digital User Office

  • Digital User Office
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI)
Rechercher
Paul Scherrer Institut (PSI)

Hauptnavigation

  • Research at PSIOuvrir ce point de menu principal
    • Research Initiatives
    • Research Integrity
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • PSI-FELLOW
    • PSI Data Policy
  • Research Divisions and LabsOuvrir ce point de menu principal
    • Overview
    • Research with Neutrons and Muons
    • Photon Science
    • Energy and Environment
    • Nuclear Energy and Safety
    • Biology and Chemistry
    • Large Research Facilities
  • Facilities and InstrumentsOuvrir ce point de menu principal
    • Overview
    • Large Research Facilities
    • Facilities
    • PSI Facility Newsletter
  • PSI User ServicesOuvrir ce point de menu principal
    • User Office
    • Methods at the PSI User Facilities
    • Proposals for beam time
    • Proposal Deadlines
    • Data Analysis Service (PSD)
    • EU support programmes
  • DE
  • EN
  • FR

Digital User Office (mobile)

  • Digital User Office

Vous êtes ici:

  1. PSI Home
  2. Labs & User Services
  3. PSD
  4. LSB
  5. Detectors
  6. Projects
  7. EIGER

Navigation secondaire

Detectors Group

  • Projects Sous-menu élargi
    • MYTHEN
    • GOTTHARD
    • EIGER
    • JUNGFRAU
    • MOENCH
    • AGIPD
    • Documentation
    • Software Releases
  • Research
  • Scientific Highlights and News
  • Publications
  • People

Info message

Ce contenu n'est pas disponible en français.

EIGER: Extremly hIGh rate detEctoR

banner detectors.jpg
EIGER is a Single-Photon Counting (SPC) pixel detector being developed at the Paul Scherrer Institut for synchrotron applications. In SPCs, the counter of a pixel is increased by one if the signal generated by the interaction of a photon with the sensitive part of the detector exceeds a set threshold. The possibility of setting the threshold according to the experimental conditions allows for background rejection.
Its working principle is similar to the PILATUS detector, with 5 times more pixels per unit area and a frame rate up to 100 times faster.


Detector description

The detector group at PSI is currently in the production stage of many Eiger systems for synchrotron applications.

The basic unit system is the EIGER module, consisting of 500 kpixels of 75x75 um2 size, with a sensitive area of 8x4 cm^2.
The module has on board intelligence provided by 6 FPGAs and memories. This means that frames can be stored and summed before transferring them out of the detector through 2 Ethernet connectors.
In addition, count rate corrections could be performed on board on the single frames before summation.

The modules are building blocks of larger systems, where acquisition, readout and data transfer are performed in fully parallel mode i.e. the frame rate of the system is not dependent on the detector size.
We have produced a 1.5 M system which is now installed at the https://www.psi.ch/sls/csaxs at the Swiss Light Source and will serve as wide angle scattering detector.
The largest system we are producing is a 9M system, which will be used as a small angle scattering detector at the same beamline.
Picture of an EIGER module. The sensitive part has dimentions 8x4 cm^2.
Picture of an EIGER module. The sensitive part has dimentions 8x4 cm^2.
Picture of the 1.5M EIGER detector, consisting of three modules. The acquisition and readout are carried out in parallel with no effect on the frame rate of larger systems.
Picture of the 1.5M EIGER detector, consisting of three modules. The acquisition and readout are carried out in parallel with no effect on the frame rate of larger systems.


Detector characteristics

  • Pixel size 75x75 um^2
  • Noise: depending on settings but 70-200 e- (250-700 eV)
  • Sensitive to energies > 2.5 keV
  • Pixel to pixel threshold inhomogenities: 70-150 eV
  • Counter depth: configurable in 4/8/12 bit mode.
  • Summing frames on board allows 32 bit depth counter
  • Countinuos applications possible: 4 us dead time between frames.
  • Frame rate: up to
    • 23 kHz in 4 bit, burst mode,
    • 7 kHz in 12 bit, burst mode
    • 2 kHz countinuos, 12 bit, 10 Gb Ethernet
    • 250 Hz continuos, 12 bit, 1 Gb Ethernet
  • Count rate capabilities: 0.2-0.7 MHz/pixel @ 90% linearity

Applications

  • Coherent diffractive imaging (CDI) and ptychography
  • Small Angle X-ray Scattering (SAXs)
  • Protein Crystallography (PX)
  • Xray Photon Correlation Spectroscopy (XPCS)
Results showing the performance of Eiger in ptychography can be found https://www.psi.ch/coherent-x-ray-scattering/fast-scanning-coherent-x-r…


Perfomances

The plots show the linear calibration of the threshold settings as a function of the photon energy for different preamplifier gain setting. By changing the preamplifier one is sensitive to different photon energies.
The plots show the linear calibration of the threshold settings as a function of the photon energy for different preamplifier gain setting. By changing the preamplifier one is sensitive to different photon energies.
Noise (measured in e-) for the different preamplifier settings. The noise is as low as 70 e- for high gains and 200 e- for lower gains.
Noise (measured in e-) for the different preamplifier settings. The noise is as low as 70 e- for high gains and 200 e- for lower gains.
Detected rate/pixel over incident rate/pixel. The detector becomes inefficient at high photon fluxes as the circuitry in the pixel is insensitive to the arrival of newer photons while the signal is still above threshold. The effect is more pronounced at higher gain as the signal stays longer above the threshold.
Detected rate/pixel over incident rate/pixel. The detector becomes inefficient at high photon fluxes as the circuitry in the pixel is insensitive to the arrival of newer photons while the signal is still above threshold. The effect is more pronounced at higher gain as the signal stays longer above the threshold.
Image of a floral composition collected with the 1.5M EIGER system, flat field corrected.
Image of a floral composition collected with the 1.5M EIGER system, flat field corrected.

Documentation

EIGER  

Publications

  • Tinti G, Fröjdh E, van Genderen E, Gruene T, Schmitt B, de Winter DAM, et al.
    Electron crystallography with the EIGER detector
    IUCrJ. 2018; 5(2): 190-199. https://doi.org/10.1107/S2052252518000945
    DORA PSI
  • Zinn T, Homs A, Sharpnack L, Tinti G, Fröjdh E, Douissard P-A, et al.
    Ultra-small-angle X-ray photon correlation spectroscopy using the Eiger detector
    Journal of Synchrotron Radiation. 2018; 25(6): 1753-1759. https://doi.org/10.1107/S1600577518013899
    DORA PSI
  • Tinti G, Marchetto H, Vaz CAF, Kleibert A, Andrä M, Barten R, et al.
    The EIGER detector for low-energy electron microscopy and photoemission electron microscopy
    Journal of Synchrotron Radiation. 2017; 24(5): 963-974. https://doi.org/10.1107/S1600577517009109
    DORA PSI
  • Tinti G, Bergamaschi A, Cartier S, Dinapoli R, Greiffenberg D, Johnson I, et al.
    Performance of the EIGER single photon counting detector
    Journal of Instrumentation. 2015; 10(3): C03011 (8 pp.). https://doi.org/10.1088/1748-0221/10/03/C03011
    DORA PSI
  • Tinti G, Bergamaschi A, Cartier S, Dinapoli R, Greiffenberg D, Horisberger R, et al.
    Similarities and differences of recent hybrid pixel detectors for X-ray and high energy physics developed at the Paul Scherrer Institut
    Journal of Instrumentation. 2015; 10: C04043 (7 pp.). https://doi.org/10.1088/1748-0221/10/04/C04043
    DORA PSI
  • Guizar-Sicairos M, Johnson I, Diaz A, Holler M, Karvinen P, Stadler H-C, et al.
    High-throughput ptychography using Eiger: Scanning X-ray nano-imaging of extended regions
    Optics Express. 2014; 22(12): 14859-14870. https://doi.org/10.1364/OE.22.014859
    DORA PSI
  • Johnson I, Bergamaschi A, Billich H, Cartier S, Dinapoli R, Greiffenberg D, et al.
    Eiger: A single-photon counting x-ray detector
    Journal of Instrumentation. 2014; 9(5): C05032. https://doi.org/10.1088/1748-0221/9/05/C05032
    DORA PSI
  • Dinapoli R, Bergamaschi A, Greiffenberg D, Henrich B, Horisberger R, Johnson I, et al.
    EIGER characterization results
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2013; 731: 68-73. https://doi.org/10.1016/j.nima.2013.04.047
    DORA PSI
  • Johnson I, Bergamaschi A, Buitenhuis J, Dinapoli R, Greiffenberg D, Henrich B, et al.
    Capturing dynamics with Eiger, a fast-framing X-ray detector
    Journal of Synchrotron Radiation. 2012; 19(6): 1001-1005. https://doi.org/10.1107/S0909049512035972
    DORA PSI
  • Radicci V, Bergamaschi A, Dinapoli R, Greiffenberg D, Henrich B, Johnson I, et al.
    EIGER a new single photon counting detector for X-ray applications: performance of the chip
    Journal of Instrumentation. 2012; 7(2): C02019 (10 pp.). https://doi.org/10.1088/1748-0221/7/02/C02019
    DORA PSI
  • Dinapoli R, Bergamaschi A, Henrich B, Horisberger R, Johnson I, Mozzanica A, et al.
    EIGER: Next generation single photon counting detector for X-ray applications
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2011; 650(1): 79-83. https://doi.org/10.1016/j.nima.2010.12.005
    DORA PSI
  • Lehmann EH, Tremsin A, Grünzweig C, Johnson I, Boillat P, Josic L
    Neutron imaging - Detector options in progress
    Journal of Instrumentation. 2011; 6(1): C01050. https://doi.org/10.1088/1748-0221/6/01/C01050
    DORA PSI

Team

Personne Position Phone Nr. Courriel
Dr. Lars Erik Fröjd
Scientist
+41 56 310 32 68
erik.froejdh@psi.ch

Sidebar

Contact

Dr. Bernd Schmitt
Paul Scherrer Institut
5232 Villigen-PSI
Switzerland
Telephone:
+41 56 310 2314
E-mail:
bernd.schmitt@psi.ch

Photon Science Division

Homepage of PSI Division Photon Science (PSD)

top

Pied de page

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Suisse

Téléphone: +41 56 310 21 11
Téléfax: +41 56 310 21 99

Comment nous trouver 
Formulaire de contact

Centre de visiteurs psi forum
Laboratoire élèves iLab (en allemand)
Centre de protonthérapie
Centre de Formation du PSI (en allemand)
PSI Guest House (en anglais)
PSI Gastronomie (en allemand)

Service & Support

  • ​Annuaire/Liste de contacts
  • User Office
  • Accelerator Status
  • Publications du PSI
  • Fournisseurs
  • E-facture
  • Computing (en anglais)
  • Sicherheit (en allemand)

Carrière

  • Travailler au PSI
  • Offres d'emploi
  • Formation initiale et formation continue
  • Formation professionnelle (en allemand)
  • Centre de Formation du PSI

Pour les médias

  • Le PSI en bref
  • Chiffres et faits
  • Contact destiné aux médias
  • Communiqués de presse
  • Social Media Newsroom

Suivez le PSI: Twitter (en allemand) LinkedIn Youtube Issuu RSS

Footer legal

  • Impressum
  • Conditions d'utilisation
  • Login éditeurs