Aller au contenu principal
  • Paul Scherrer Institut PSI
  • PSI Research, Labs & User Services

Digital User Office

  • Digital User Office
  • DE
  • EN
  • FR
Paul Scherrer Institut (PSI)
Rechercher
Paul Scherrer Institut (PSI)

Hauptnavigation

  • Research at PSIOuvrir ce point de menu principal
    • Research Initiatives
    • Ethics and Research integrity
    • Scientific Highlights
    • Scientific Events
    • Scientific Career
    • PSI-FELLOW
    • PSI Data Policy
  • Research Divisions and LabsOuvrir ce point de menu principal
    • Overview
    • Research with Neutrons and Muons
    • Photon Science
    • Energy and Environment
    • Nuclear Energy and Safety
    • Biology and Chemistry
    • Scientific Computing, Theory and Data
    • Large Research Facilities
  • Facilities and InstrumentsOuvrir ce point de menu principal
    • Overview
    • Large Research Facilities
    • Facilities
    • PSI Facility Newsletter
  • PSI User ServicesOuvrir ce point de menu principal
    • User Office
    • Methods at the PSI User Facilities
    • Proposals for beam time
    • Proposal Deadlines
    • Data Analysis Service (PSD)
    • EU support programmes
  • New ProjectsOuvrir ce point de menu principal
    • SLS 2.0
    • IMPACT
  • DE
  • EN
  • FR

Digital User Office (mobile)

  • Digital User Office

Vous êtes ici:

  1. PSI Home
  2. Labs & User Services
  3. PSD
  4. SLS
  5. MS
  6. Endstations
  7. Surface Diffraction
  8. SD - Detectors

Navigation secondaire

MS

  • Status
  • User Information
    • Operation Schedule
    • Manuals
    • Computing/Controls
  • Staff
  • Beamline Layout
    • Source
    • Optics
  • Endstations Sous-menu élargi
    • Powder Diffraction
      • PD - Description
      • PD - Detectors
      • PD - Mesquik
      • PD - Publications
      • PD - Research
    • Surface Diffraction Sous-menu élargi
      • SD - Description
      • SD - Detectors
      • SD - Publications
      • SD - Research
  • Research
  • Publications
  • Scientific Highlights and News
  • Contacts

Info message

Ce contenu n'est pas disponible en français.

Detectors

General description

The surface diffractometer is equipped with a pixel detector constructed by the SLS detector group. This second-generation PILATUS II detector was installed in October 2005 (see Figure below) and uses photon-counting technology with essentially no background noise.

Specifications

Spec. Value
Active area 487 x 195 pixels (= 95 kPixel)
Pixel size 172.0 mm x 172.0 mm
Dynamic range 106 (220)
Maximum count rate 106 cts/s
Location 1140.8 +/- 0.25 mm from the centre of the diffractometer (gamma axis)
Subtended angle 4.205o x 1.684o (0.008634o/pixel)
Back to top

Mounting

The detector is mounted on the delta arm with its center nominally along the nu-rotation axis. The detector can, however, be shifted laterally both up/down and sideways using positioning screws on the detector holding bracket.

The detector flight tube has 3 extension pieces of lengths 200, 100, and 50 mm. When all three pieces are used and a compact detector 4-slit module is mounted on the front, the slit module is approximately 60 mm from the center of the diffractometer.
The 100 kPixel Pilatus II detector setup. The flight tube length can be varied in steps of 50 mm between 725 and 1075 mm, using any combination of the three extension tubes (50, 100, and 200 mm).

Back to top

Radiation protection system

At the front of the detector flight tube of the diffractometer is a housing containing horizontal and vertical slits, a slow (2mm-thick steel) removable beam stop plate, and a mini ionization chamber. The purpose of the mini-IO is to monitor whether too much radiation (e.g., full focussed beam) is incident on the pixel detector, which can then trigger the fast photon shutter to close if a threshold value is exceeded.

Inadvertent experiments testing the radiation hardness of Pilatus II have shown it to be remarkably robust. However, we know that a few seconds exposure with the full beam can lead to permanent damage. This should of course be avoided at all costs, but human error, particularly at 2 o'clock in the morning after 20 hours without sleep, is inevitable.

Accordingly, we have installed a simple widget system that monitors the analog output from the mini-IO and closes the fast photon shutter (F-PS) if the signal exceeds a given value.
Radiation protection system
Radiation protection system
The mini-IO protection widget. The ion chamber monitor widget will close the fast photon shutter if the analog current reading exceeds the value given in the field "High" and the yellow field in Auto-Shut shows "enabled".

The widget is available under Top level launcher/in-situ surface diffractometer/ion chamber monitor. To establish what threshold should be entered into the "High" field, turn up the voltage of the ion chamber controller S-2341A in the main rack in EH3 to 300 V and set the current sensitivity to 10-8. Insert filters upstream (using the filter widget) to a transmission of 10-3. Then disable the "Auto Shut" feature on the widget, close the slow beam stop plate (and the detector slits, to be on the safe side), and slowly move step by step the diffractometer so that the detector arm moves into the direct beam. At GAM = DEL = 0 (assuming correctly adjusted motor values), note the raw or monitored ion chamber value in the widget. Enter half this value into the "High" field. Typical values appear to be about 0.5. Lastly, don't forget to enable the "Auto Shut" feature on the widget again.

Back to top

Operating methods

Using the PILATUS detector, we have been able to record CTRs and reflectivity curves with unsurpassed quality and speed. Typical procedures using this novel detector and recording geometry are described in an Acta Crystallographica A paper here and a more recent Journal of Applied Crystallography paper here.

Back to top

Flatfield correction and trimfiles




Flatfield correction images are recorded at the energy at which the experiments are being carried out. Typically, one places a scattering object in the beam, moves the detector to a position where the scatter is homogeneous and contains no Debye-Scherrer cones or diffraction spots, and records enough images so that the statistics are sufficient for the job at hand. An example of a flatfield image at 3 different intensity scale ranges is shown below

Flatfield image recorded at 16 keV. Click to enlarge each image. Note the three different intensity scales. The 16 different regions are evident from the less sensitive border pixels. Some minor damage is also noticeable.

Users can upload trimfiles into the detector control software, which act as high-pass filters for suppressing fluorescence signal. The response falloff has about a 500 eV width, and trimfiles exist for 6, 9, 12, and 16 keV.

A description of how to record flatfield and trim files can be found here.

Back to top

On-line image viewer OLIVA

A MATLAB program has been written, that allows one to view the most recently recorded pixel image. The program is called OLIVA. Here is a description of how to run OLIVA:

In a shell on PC6025, type in: cd /sls/X04SA/data/x04sa/sddir/software/matlab/ In this directory, call up MATLAB by typing in: matlab & In the MATLAB command shell, type in: oliva
OLIVA on-line viewer panel
OLIVA on-line viewer panel
The program needs to know where to look for the most recent image to display. The field in the top-left hand corner of the OLIVA panel contains the "updated image information file". By clicking on the file navigator button (the grey box with 3 dots), navigate to and select:

/sls/X04SA/Data1/ES3/expdata/mysample_mydate/pixel/images/spec_image_info.dat

whereby mysample_mydate is the name of your project that you created using the SPEC command sdStartup, an example of which might be ybco_20070610 (a beamtime on YBCO started on 10th June, 2007)

You can run/pause the program by clicking on the Run/Pause buttons at the top-right.

Back to top

Pixel image MATLAB analysis

Atomic functions written in MATLAB, which can be applied for data analysis and extraction of images recorded using the pixel detector are available here. Chris Schlepuetz has written a sophisticated GUI in MATLAB for extracting data and creating CTR or SSR data files, which uses the scan logs created by SPEC at our beamline. A screenshot of the GUI can be found here. Anyone interested in using this program should contact Chris Schlepuetz or Phil Willmott

Back to top

Troubleshooting

The pixel control widget panel. Click to enlarge.
  • Control computer "NOT MASTER" If, when you try to record an image via SPEC (and you have chosen connect on the trigger pull-down menu), the pixel control widget shows a red panel containing the message "NOT MASTER" (this is normally blue and shows "Ready"), this unfortunately means you have to restart the pixel control program tvx on the computer PC5888 (via remote connection using PC6025)
  • Widget freezing It can occur that the control computer PC5758 loses communication with the pixel computer. This is evident by the pixSNL dot at the top-right hand corner of the pixel control widget not continually hopping left and right (i.e., it indicates that communication is frozen). If this case, you must reboot the ES3 VME-crate. To do this, open a shell in PC5758 and type
  • rmc X04SA-VME-ES3
  • This brings up a "remote minicom" shell (hence rmc), in which you then type
  • CTRL-x
  • which will begin the rebooting of the ES3 crate. This takes a minute or two to complete, during which, the fields for those EPICS channels on display which are connected to ES3 will go white. You can then exit the rmc, by typing
  • CTRL-a, then q
  • after which you should confirm you want to exit without resetting.
Back to top

Sidebar

User Contact Points at PSI

PSI User Office
DUO Login

Call for Proposals

PX Beamlines: Call is open for proposals
More Information

All other Beamlines
08 February 2020: Call is open for proposals
More Information

Upcoming Events

Get a list of upcoming scientific conferences and seminars

PSI User Facilities Newsletter

Current News from PSI photon, neutron and muon user facilities
top

Pied de page

Paul Scherrer Institut

Forschungsstrasse 111
5232 Villigen PSI
Suisse

Téléphone: +41 56 310 21 11
Téléfax: +41 56 310 21 99

Comment nous trouver 
Contact

Centre de visiteurs psi forum
Laboratoire élèves iLab (en allemand)
Centre de protonthérapie
Centre de Formation du PSI
PSI Guest House (en anglais)
PSI Gastronomie (en allemand)
psi forum shop

Service & Support

  • Annuaire
  • User Office
  • Accelerator Status
  • Publications du PSI
  • Fournisseurs
  • E-facture
  • Computing (en anglais)
  • Sicherheit (en allemand)

Carrière

  • Travailler au PSI
  • Offres d'emploi
  • Formation initiale et formation continue
  • Career Center
  • Formation professionnelle (en allemand)
  • Centre de Formation du PSI

Pour les médias

  • Le PSI en bref
  • Chiffres et faits
  • Le coin médias
  • Communiqués de presse
  • Réseaux sociaux

Suivez le PSI: Twitter (in English) LinkedIn Youtube Facebook Instagram Issuu RSS

Footer legal

  • Impressum
  • Conditions d'utilisation
  • Login éditeurs