Beamline Status
| Resource | Status | Description |
|---|---|---|
| Status optics and monochromator | OK | The beamline features a double-crystal fixed-exit monochromator for X-rays in the range from 6 to 17 keV. Vertical focussing is achieved by a dynamically bendable mirror. The beam is stabilized with a feedback system. |
| Status sample and environment | OK | The focussed beam size on the sample is 85 μm by 10 μm at the High-Resolution Diffractometer (HRD) focus, it is 25 (10) μm by 5 μm at the Microdiffractometer (MD2) focus. Liquid nitrogen (100 K) or room temperature measurements possible. |
| Status endstations and detectors | OK | Pilatus 6M, Ketek Fluorescence detector at the HR station; Mar225 CCD and MD2 Ketek Fluorescence detector at the MD2 station. |
| Status sample changer CATS | OK | Sample changer at HRD in operation, please refer to the CATS page. |
| Status analysis tools | OK | XDS, MOSFLM, automatic data reduction: go.com |
| Status operation | OK | User operation, see the schedule |
| Legend | OK | PROBLEMS | ERROR |
|---|
Current Status
- Two new KETEK/XIA detector combinations available for fluorescence scans at HRD and MD2
- CATS operational at the HRD; no sample changer at the MD2
News
May 2011
- Pilatus 6M upgraded to 25 MHz operation. Minimum exposure time now 0.04 s.
Beamline Info
- Parallel XDS version for processing of PILATUS data on x06sa-cn-1...4
- Templates in /exchange/mx/templates/XDS/PILATUS .
- Start XDS by typing xds_par and 'enter'
- Please notify us two weeks in advance in case of cancellation of shifts.
- Otherwise re-scheduling might not be possible.
- Please register your beamline-related publications via the DUO.
- Proposals -> Publications.
- Please make sure to inform your local contact well in advance if you have special requirements for the night shift,
- (e.g., beam size, equipment,...) as the "default" on-call support only is scheduled from 7 am to 11 pm.
- Information on Usage and Monitoring of IT Resources at PSI.
- Cancellation of shifts.
Older news
October/November 2010
- New sample table to position sample using SmarAct devices. This new goniometer head is faster and more precise.
- XRF Detector at the high-resolution diffractometer is now a Vortex detector controlled by the same application as in beamlines X06DA and X10SA.
September 2010
- The X06SA beamline has a new set of computing nodes which have replaced the previous cluster
- the new cluster consists of 4 blades each with 12 cores (6 real and 6 virtual) and 24 GB of RAM
- the storage has also been upgraded with a much faster backend and it has also been consolidated together with the storage at beamline X10SA
- the X-terminals at the beamline have been replaced by normal computers which will provide a much better performance when running graphical applications such as Coot, Pymol etc.
- NOTE as a side effect, the user must
sshto the computing nodes in order to get access to the parallel processing capabilities of XDS or go.com
- NOTE as a side effect, the user must
August 2010
- CATS sample changer system in operation on advance request.
- Please inform your local contact if you want to use it. Currently only MD caps and vials can be supported.
- New versions of clara and peter installed.
- New software available , e.g., Il Milione
- Check out the xtallography information platforms, the CCP4 user community wiki and the XDS wiki
- List of earlier changes & updates